ICR/P error #-2147418113 with IBM Datacap Taskmaster Capture
Abstract
The ICR/P Parascript option gives an error when recognizing a field and the batch aborts. The error text is:
ICR/P error #-2147418113: ICR_P: Incorrect field type, or this field type is not registered in a system.
Cause
Taskmaster cannot locate field type information.
Resolving the problem
To resolve:
- 1. Edit the registry by adding a new Key HKLM\SOFTWARE\Parascript\FieldScript 3.0 (Parascript should already exist; do not name the key FieldScript 4.0; or FieldScript 4.1).
- Edit the registry by adding a new Key HKLM\SOFTWARE\Parascript\FieldScript 3.0\FieldTypes.
- Edit the registry under the newly created key Field Types by adding a new String Value called Directory.
- Update value of (STRING) Directory to point to C:\Datacap\dcshared\ICRP\FieldScript4.1\FieldTypes
- In Command Prompt (use Run as Administrator to start the program if UAC is enabled) the following command:
C:\Datacap\dcshared\ICRP\FieldScript4.1\BIN\FieldTypeInstaller.exe /ia
/d"C:\Datacap\dcshared\ICRP\FieldScript4.1\FieldTypes"
Note: A valid SoftKey must be installed on the machine running ICR/P recognition.
No comments: